+91-7011441567
  RZ-A/23-24 Indira Park Uttam Nagar New Delhi-110059


MIR New Spirolab®


MIR Spirolab®

Fast, simple, durable diagnostic spirometer

 

 

Features

 

  • FVC, FEV1, IVC, MVV, PRE/POST Bronchodilator comparison with a wide range of selectable parameters
  • Long life Rechargeable Battery
  • Color Touchscreen 7 inches display
  • Direct connection to external USB Printer
  • 10,000 Spirometry tests or 500 hours of Oximetry recording
  • Wireless Real Time test on PC via Bluetooth
  • Fast and silent built–in printer with customizable printout format

 

 

Fast and intuitive

for modern professionals

Each function can be activated by a simple touch on the intuitive bar menu always presents on the screen.

 

 

Suitable for children

Patented pediatric incentive

Directly on the screen to improve patient compliance during a Spirometry test.

 

 

Technical Specification - Spirolab Spirometry

 

Power supply

:

Rechargeable battery and mains power

Temperature sensor

:

Semiconductor (0-45°C)

Flow sensor

:

bi-directional digital turbine

Flow range

:

±16L/s

Volume accuracy

:

±3% or 50mL

Flow accuracy

:

±5% or 200mL/s

Dynamic resistance

:

<0.5 cmH2O/L/s

Connectivity

:

USB 2.0, Bluetooth® 2.1

Display

:

7inch colour touch screen LCD, 800x480 resolution

Mouthpieces

:

Ø 30 mm (1.18 inch)

Dimensions

:

220 x 210 x 51 mm (8,66 x 8,26 x 2in)

Weight

:

1450 g (battery pack included) (3,1lb)

 

 

Spirometry parameters:

 

FVC, FEV1, FEV1/FVC, FEV1/VC, PEF, FEF25, FEF50, FEF75, FEF25–75, FEF75–85, Lung Age, Extrapolated Volume, FET, Time to PEF, FEV0.5, FEV0.5/FVC, FEV0.75, FEV0.75/FVC, FEV2, FEV2/FVC, FEV3, FEV3/FVC, FEV6, FEV1/ FEV6, FEV1/PEF, FEV1/FEV0.5, FIVC, FIV1, FIV1/FIVC, PIF, FIF25, FIF50, FIF75, FEF50/FIF50, VC, IVC, IC, ERV, IRV, Rf, VE, VT, tI, tE, VT/tI, tE/tTOT, MVV (measured), MVV (calculated).

 

 

Technical Specification - Spirolab Oximetry (Optional)

 

SpO2 range

:

0-99%

SpO2 accuracy

:

± 2% between 70-99% SpO2

Pulse Rate range

:

18-300 BPM

Pulse Rate accuracy

:

± 2BPM or 2% whichever is greater

Memory capacity

:

up to 500 hours oximetry

 

 

Oximetry parameters (optional):

 

%SpO2 and Pulse Rate (Min, Max, Average), Test duration, Total SpO2 Events, T90% (SpO2 time ≤89%), T89% (SpO2 time ≤88%), T40 (Bradycardia duration with Pulse Rate <40 BPM), T120 (Tachycardia duration with Pulse Rate >120 BPM)



Copyright © S.S.Medical 2018 All Rights Reserved  |   Website Designing By : SriRam Soft Solutions Pvt. Ltd.