Sibelmed DATOSPIR Touch
Designed to meet your needs
Main
Features
Parameters
FVC / Bronchodilation FVC (l)
FEV1 (l) FEV1/FVC (%) PEF (l/s) FEF50%(l/s) FEF25-75% (l/s) FEV6 (l)
FEV1/FEV0.5 (-) PEFT Vext (l) FIVC (l) FIF50% FEF50/FIF50 QC Grades FEV.5 (l)
FEV3 (l) FEV.5/FVC (%) FEV3/FVC (%) FEV1/VC (%) FEV1/FEV6 (%) FEV1/PEF (%) FEV1/FIV1
(-) PEF/PIF (-) FEF25% (l/s) FEF75% (l/s) FEF75-85% (l/s) FET25-75 (s) FET100
(s) FIV1 (l) FIV1/FIVC (%) PIF (l/s) MTT (s) MVVInd (l/min) COPD Index (%) Lung
age (years) VC VC (l) TV (l) ERV (l) IRV (l) IC (l) Ti (s) Te (s) Tt (s) Ti/Tt
(%) MVV MVV (l/min) Br./min (Br/min) Bronchoconstriction FVC (l) FEV1 (l) PEF
(l/s) FEF25-75% (l/s) PDx Sp02 Maximum SpO2 (%) Average SpO2 (%) Minimum SpO2
(%) SpO2 Std Dev (%) Maximum PR (BPM) Average PR (BPM) Minimum PR (BPM) PR Std
Dev (BPM) CT90 (%) CT80 (%) CT70 (%) ODI-4 ODI-3 ODI-2 Test time (hh:mm:ss)
Connectivities
Operating
Modes
Occupational Health Mode (OC): Intended for
occupational health clinics and insurance companies. Performs FVC and
bronchodilation tests quick and easy for early detection of work-related lung
diseases. Primary Care Mode (PC): Intended for Primary Care centers. Performs
the main tests with interactive help in order to obtain spirometries with
similar quality to the ones performed at a specialized center (Spirometry
quality control). Helps to detect and follow-up most common respiratory
diseases such as Asthma or COPD. Diagnostic Mode (DG): Intended for Pulmonary
Function Laboratories specialized in lung diseases, providing the highest
spirometry test control. It is the most complete mode that includes
Bronchoconstriction Test, Occupational Health and Primary Care modes among
other options.
Transducer
Technical
Specifications
Flow transducer |
: |
Fleisch, turbine or disposable (Lilly) |
Measurement range (BTPS) |
: |
Flow 0 ± 16 l/s; Volume 0 to 10 l |
Accuracy (BTPS) |
: |
Flow 5% or 200 ml/s; Volume: 3% or 50ml (ATS/ERS) |
Display |
: |
640 x 480 px and 5.7 inch high resolution color VGA touchscreen |
Printer |
: |
112 mm thermal graphic printer |
Rechargeable battery |
: |
Ni-Mh 10.8V 2500mAh. Duration 1.5h approx |
No. of maneuvers per patient |
: |
8 FVC, 8 VC, 8 MVV |
Operating Temperature-Humidity |
: |
5 to 40ºC. < 85% (without condensation) |
Power supply |
: |
100 to 240V, 50 to 60Hz |
Power |
: |
30W |
Dimensions |
: |
195 x 270 x 100 mm |
Weight |
: |
1.7 kg |
Storage temperature |
: |
-20ºC to 70ºC |
Directive |
: |
93/42/CEE on Medical Devices, Class IIa Product |
Standards |
: |
EN 60601-1:2006, EN 60601-1-2:2007, EN 60601-1-6:2007, EN ISO
10993-1:2009, EN ISO 23747:2009, EN ISO 26782:2009, EN 62304:2006, EN
62366:2008, EN 1041:2008, EN 980:2008, EN ISO 14971:2009, EN ISO 9919:2009 |
References
Spirometry
quality control program:
Accuracy verification program:
ATS/ERS 2005 recommends to check periodically
volume spirometers.
In order to check that the transducer is measuring correctly, the spirometer includes a simple verification procedure, to be performed in a few seconds if required.
Copyright © S.S.Medical 2018 All Rights Reserved | Website Designing By : SriRam Soft Solutions Pvt. Ltd.