+91-7011441567
  RZ-A/23-24 Indira Park Uttam Nagar New Delhi-110059


KORRâ„¢ CardioCoachâ„¢


KORRâ„¢ CardioCoachâ„¢

Simple & Accurate VOâ‚‚ Max Testing

 

Features

  • VOâ‚‚ Max and Sub Max
  • AT, AeT, Peak VOâ‚‚
  • Precise Target Heart Rates
  • Calories Burned During Exercise

 

The CardioCoachâ„¢ delivers simple and accurate fitness testing based on oxygen consumption. This data can be used as the foundation for customized exercise programs that truly meet the needs of the individual. It is so simple to use that any of your current employees can perform a VOâ‚‚ Max test. It is affordable, allowing even small gyms, personal trainers and educators to own state of the art VOâ‚‚ Max test equipment.

 


Mixing chamber Technology

A mixing chamber is considered the “Gold Standard” for VO₂ Max measurements. In the past, this system has been complicated and expensive, making it only practical to train professional athletes and for use in research departments.KORR advancements in technology make this equipment feasible for gym owners and trainers at any level of expertise to own.

 

Self-Calibrating

Adjustments for barometric pressure, temperature, and humidity are key to an accurate VOâ‚‚ measurement. The CardioCoachâ„¢ measures these parameters during each routine calibration cycle, then automatically compensates to standard (STPD) conditions.

 

Simple

The CardioCoachâ„¢ has a simple user interface that assists the operator from start to finish.No training or certification is necessary.

 

Workouts

CardioCoach™ software is available to provide your clients with workouts at no additional cost to them.Pre-loaded plans will apply your client’s test results to workouts designed to meet particular goals such as training for a race, cycling, or weight loss.The software will also guide trainers through designing customized workouts

 

No Contracts

KORR does not lock customers in to ongoing service contracts.

 

Accurate

The CardioCoachâ„¢ has been independently validated at the University of Southern California and Oregon State University.

 

Specifications

 

Oâ‚‚ Sensor

 

 

Type  

:

Galvanic Fuel Cell

Accuracy      

:

±0.2% O₂

Resolution   

:

0.01% Oâ‚‚

Range

:

0 to 30% Oâ‚‚

Average Sensor Life           

:

24 months

 

Air Flow Sensor

 

 

Type  

:

Fixed-orifice Differential Pressure Pneumotach

Accuracy      

:

±2% of reading

Resolution   

:

0.01 LPM

Range

:

-40 to 500 LPM

Breath Rate  

:

5 to 50 breaths/minute

Tidal Volume

:

200 to 9000 ml

 

Physical Dimensions

 

 

Size   

:

15" x 15" x 4"

Weight          

:

7 lbs 14 oz (3.5 kgs)

 

Accuracy VO2 Max

 

 

R value         

:

0.94

Percentage error     

:

3%

 

CO2 Sensor (CardioCoachâ„¢ CO2 only)

Method          

:

Non-dispersive Infrared Absorption

Calibration   

:

3-point calibration

Respiration Rate     

:

150 bpm

Measurement Range         

:

0-76 mmHg

Accuracy      

:

±2 mmHg plus ± 5% of reading

Resolution   

:

1 mmHg

Flow Rate     

:

50 ml/min ± 10 ml/min

 



Copyright © S.S.Medical 2018 All Rights Reserved  |   Website Designing By : SriRam Soft Solutions Pvt. Ltd.