KORRâ„¢ CardioCoachâ„¢
Simple & Accurate VOâ‚‚ Max Testing
Features
The CardioCoachâ„¢
delivers simple and accurate fitness testing based on oxygen consumption. This
data can be used as the foundation for customized exercise programs that truly
meet the needs of the individual. It is so simple to use that any of your
current employees can perform a VOâ‚‚ Max test. It is affordable, allowing
even small gyms, personal trainers and educators to own state of the art VOâ‚‚ Max test
equipment.
Mixing chamber Technology
A mixing chamber is
considered the “Gold Standard†for VO₂ Max measurements. In the past, this
system has been complicated and expensive, making it only practical to train
professional athletes and for use in research departments.KORR advancements in
technology make this equipment feasible for gym owners and trainers at any
level of expertise to own.
Self-Calibrating
Adjustments for
barometric pressure, temperature, and humidity are key to an accurate VOâ‚‚ measurement. The CardioCoachâ„¢
measures these parameters during each routine calibration cycle, then
automatically compensates to standard (STPD) conditions.
Simple
The CardioCoachâ„¢
has a simple user interface that assists the operator from start to finish.No
training or certification is necessary.
Workouts
CardioCoachâ„¢
software is available to provide your clients with workouts at no additional
cost to them.Pre-loaded plans will apply your client’s test results to workouts
designed to meet particular goals such as training for a race, cycling, or
weight loss.The software will also guide trainers through designing customized
workouts
No Contracts
KORR does not lock
customers in to ongoing service contracts.
Accurate
The CardioCoachâ„¢
has been independently validated at the University of Southern California and
Oregon State University.
Specifications
Oâ‚‚ Sensor |
|
|
Type |
: |
Galvanic Fuel Cell |
Accuracy |
: |
±0.2% O₂ |
Resolution |
: |
0.01% Oâ‚‚ |
Range |
: |
0 to 30% Oâ‚‚ |
Average Sensor Life |
: |
24 months |
Air Flow Sensor |
|
|
Type |
: |
Fixed-orifice Differential Pressure Pneumotach |
Accuracy |
: |
±2% of reading |
Resolution |
: |
0.01 LPM |
Range |
: |
-40 to 500 LPM |
Breath Rate |
: |
5 to 50 breaths/minute |
Tidal Volume |
: |
200 to 9000 ml |
Physical Dimensions |
|
|
Size |
: |
15" x 15" x 4" |
Weight |
: |
7 lbs 14 oz (3.5 kgs) |
Accuracy VO2 Max |
|
|
R value |
: |
0.94 |
Percentage error |
: |
3% |
CO2 Sensor (CardioCoachâ„¢
CO2 only) |
||
Method |
: |
Non-dispersive Infrared Absorption |
Calibration |
: |
3-point calibration |
Respiration Rate |
: |
150 bpm |
Measurement Range |
: |
0-76 mmHg |
Accuracy |
: |
±2 mmHg plus ± 5% of reading |
Resolution |
: |
1 mmHg |
Flow Rate |
: |
50 ml/min ± 10 ml/min |